What was found
DURING ROUTINE C CHECK INSPECTION, FOUND LEFT ELEVATOR UPPER SKIN CRACKED AT STATION XE 166.312. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGED SKIN. FABRICATED NEW SKIN AND FINGER DOUBLER. BONDED PARTS AS NEEDED. CLEANED, TREATED, PRIMED AREA AND REPAIR PART. PERFORMED BALANCE. FOUND WITHIN LIMITS MOMENT 1532.0 IN-LBS. INSTALLED NEW FASTENERS AND REPAIR PARTS AT STATION XE 132.000 - 246.000 IAW SRM 55-4-1 FIGURE 1 SHEET 1-2 ITEMS "E" & "F", SRM 55-1-0 PAGE 1, SRM 51-1-21, SRM 51-1-9 TR 51-142, SRM 51-1-9A TR 51-141, SRM 51-1-8B, SRM 5-1-11, AND SRM 51-4-4 TR 51-116 PAGES 1-4.