What was found
DURING ROUTINE C CHECK INSPECTION, FOUND RIGHT HORIZONTAL STABILIZER FRONT SPAR LOWER FITTING CRACKED AT STATION XFS 60.000. REMOVED CRACKED FITTING. INSTALLED NEW FITTING IAW SRM 51-1-20D, SRM 51-1-21, AND SRM 51-3-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE C CHECK INSPECTION, FOUND RIGHT HORIZONTAL STABILIZER FRONT SPAR LOWER FITTING CRACKED AT STATION XFS 60.000. REMOVED CRACKED FITTING. INSTALLED NEW FITTING IAW SRM 51-1-20D, SRM 51-1-21, AND SRM 51-3-1.