What was found
DURING ROUTINE C CHECK INSPECTION, FOUND FORWARD ACCESSORY COMPARTMENT LEFT CAP CRACKED STATION 55.000 - 70.000 LEFT BOTTOM LINE 45. REMOVED CRACKED CAP. INSTALLED NEW CAP IAW DC8 SRM 51-1-20D, SRM 51-3-1, REPAIR SPECIFICATION NR 2003-05, AND SMN-FORM-07 IPI NR 2009405.