What was found
DURING ROUTINE C CHECK INSPECTION, FOUND LEFT HORIZONTAL STABILIZER CAP CRACKED STATION XE 29.812. REMOVED CRACKED CAP. INSTALLED NEW CAP IAW SRM 51-1-20D, SRM 51-3-1, ATI REPAIR SPECIFICATION NUMBER 2003-05, AND SMN-FORM-07 IPI NUMBER 2009420.