What was found
DURING ROUTINE C CHECK INSPECTION, FOUND RIGHT HAND INBOARD FLAP PANEL UPPER SKIN HAS SEVERAL DENTS AT STATION XW 2.000 - STATION XW 84.000. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGED SKIN. FABRICATED NEW SKIN AND BONDED DOUBLER. CLEANED, TREATED, AND PRIMED AREA AND REPAIR PARTS. INSTALLED NEW FASTENERS AND REPAIR PARTS IAW SRM 57-7-1 FIGURE 1, SRM 51-1-21, SRM 57-7-1 FIGURE 1, SRM 51-1-9 TR 51-142, SRM 51-1-8B, AND SRM 51-1-21.