What was found
DURING ROUTINE C CHECK INSPECTION FOUND MAIN CARGO COMPARTMENT FITTING CRACKED AT STATION 912.000 LONGERON 1. REMOVED CRACKED FITTING. CLEANED, TREATED, AND PRIMED AREA. INSTALLED NEW FITTING IAW SRM 51-3-1, ATI REPAIR SPECIFICATION 2003-05, SMN-FORM-07 IPI2009624, DC8 SRM 51-1-20D, SRM 51-1-21, DC8 SRM 51-1-8B,