DURING ROUTINE C CHECK INSPECTION FOUND MAIN CARGO COMPARTMENT RIGHT HAND AFT BATHTUB FITTING CORRODED AT STATION 1530.000 LONGERON 30RIGHT. REMOVED CORRODED FITTING. CLEANED, TREATED, AND PRIMED AREA AND FITTING. INSTALLED NEW FITTING IAW SRM 51-1-21, SRM 51-3-1, SRM 51-1-20D, AND SRM 51-1-8B.