What was found
DURING ROUTINE C CHECK INSP, FOUND RT HORIZONTAL STABILIZER OTBD L/E HAS DENTS AT STATION XFS 216.250 AND XFS 222.500. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED EXISTING REPAIR. REMOVED DAMAGED AREA. PERFORMED NDT INS. NO CRACKS OR CORROSION NOTED. FABRICATED DOUBLER AND FILLERS. CLEANED, TREATED, PRIMED AREA AND REPAIR PARTS. INSTALLED NEW FASTENERS AND REPAIR PARTS IAW FORM 8110-3 DATED 02-11-2010, DWG ED-5069 DATED 01-20-2010, SRM 51-1-8B, SRM 51-1-21, SRM 51-1-20D, NDT SPM PART 06-10-01.001, SRM 51-1-8B, SRM 51-1-14, AND SRM 51-3-1.