What was found
DURING ROUTINE C-CHECK INSP, FOUND RT WING UPPER PANEL SUPPORT ANGLE CORRODED AT STA XW 5.000. REMOVED CORROSION. FOUND OUT OF LIMITS. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED ANGLE. FABRICATED NEW ANGLE. CLEANED, TERATED, AND PRIMED AREA. INSTALLED NEW FASTENERS AND NEW ANGLE IAW SRM 51-1-8, SRM 57-2-0, SRM 51-1-21, SRM 51-1-8B, SRM 51-1-21 AND SRM 57-2-0 AND SMN FORM NR 2010639.