DURING ROUTINE C-CHECK INSP FOUND MAIN CARGO COMPARTMENT FITTING CORRODED AT STATION 960.000 - 980.000 RT BOTTOM LINE 28. REMOVED CORROSION AND FOUND OUT OF LIMITS. REMOVED CORRODED FITTING. CLEANED, TREATED, AND PRIMED AERA. INSTALLED NEW FITTING IAW SRM 51-1-8, SRM 53-2-0, SRM 51-1-20D, SRM 51-1-8B, SRM 51-1-20D, SRM 51-1-21, AND SRM 51-3-1.