What was found
DURING ROUTINE C-CHECK INSP, FOUND MAIN CARGO COMPARTMENT FITTING CRACKED AT STA 700.000, LT BOTTOM LINE 23. REMOVED CORROSION AND FOUND OUT OF LIMITS. REMOVED CORRODED FITTING. CLEANED, TREATED, AND PRIMED AERA. INSTALLED NEW FITTING IAW SRM 51-1-8, SRM 53-2-0, SRM 51-1-20D, SRM 51-1-8B, SRM 51-1-20D, SRM 51-1-21, AND SRM 51-3-1.