As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING ROUTINE C-CHECK INSP FOUND CORROSION ON LOWER DRAIN VALVE SURROUNDING STRUCTURE AT STATION 1542. REMOVED CORROSION. FOUND TO BE WITHIN LIMITS. CLEANED, TREATED, PRIMED AND PAINTED AREA IAW SRM 53-00-01 FIGURE 101 REV 101, AND SRM 51-20-01 REV 101.