What was found
DURING ROUTINE C-CHECK INSP FOUND NICKS ON LT HORIZONTAL STABILIZER REMOVABLE L/E NR 332BL. BLENDED OUT NICKS. PERFORMED NDT INSP. NO CRACKS INDICATED. CLEANED, TREATED, PRIMED PART IAW SRM 55-10-01 FIGURE 101, REV 101 AND NDT D634T301 REV 93, PART 6 51-00-19.