What was found
DURING ROUTINE C-CHECK INSP FOUND DENTS IN UPPER AREA OF BULK CARGO DOOR. REMOVED DENTS. FOUND TO BE WITHIN LIMITS. PERFORMED NDT INSP. NO CRACK OR CORROSION NOTED. CLEANED, TREATED, PRIMED AND PAINTED IAW SRM 51-10-01, 51-20-01 REV101, 53-00-01 FIGURE 101 REV101, NDT D634T301 REV 93 PART 6 SUB 51-00-19, AND MM 11-00-00, REV 97.