What was found
DURING ROUTINE C-CHECK INSP FOUND SCRATCHES ON FUSELAGE FWD AND BELOW FWD CARGO DOOR CONTROL. BLENDED OUT SCRATCHES. FOUND TO BE WITHIN LIMITS. PERFORMED NDT INSPECTION, NO CRACKS OR CORROSION NOTED. CLEANED, TREATED, PRIMED AND PAINTED IAW SRM 51-10-01, 51-20-01, 53-00-01 FIGURE 101 REV101, NDT D634T301 REV 93 PART 6 SUB 51-00-19 AND MM 11-00-00 REV97.