What was found
DURING ROUTINE C CHECK INSP, FOUND SCRATCHES ON L/E OF LT STABILIZER. BLENDED OUT SCRATCHES. FOUND TO BE WITHIN LIMITS. PERFORMED NDT INSP, NO CRACKS OR CORROSION NOTED. CLEANED, TREATED, PRIMED AND PAINTED IAW SRM 51-10-01, 51-20-01 REV 101, 55-10-01 FIGURE 101 REV 101, NDT D634T301 REV 93 PART 6 SUB 51-00-19 AND MM 11-00-00 REV 97.