What was found
DURING ROUTINE C CHECK INSP FOUND SCRATCHES ON LT FUSELAGE AFT BODY FAIRING BY T/E. BLENDED OUT SCRATCHES. PERFORMED NDT INSP, NO CRACKS OR CORROSION NOTED. CLEANED, TREATED, PRIMED AND PAINTED IAW SRM 51-10-01, 51-20-01, 53-00-01 FIGURE101 REV 101, NDT D634T301 REV 93 PART6 SUD 51-00-19 AND MM 11-00-00, REV 97.