What was found
DURING ROUTINE C CHECK INSP FOUND GOUGE ON LWR FUSELAGE LT OF CTR LINE AT STATION 1619. BLENDED OUT GOUGE. FOUND TO BE WITHIN LIMITS. PERFORMED NDT INSP, NO CRACKS OR CORROSION NOTED. CLEANED, TREATED, PRIMED AND PAINTED IAW SRM 51-10-01, 51-20-01, 53-00-01 FIGURE 101 REV 101, NDT 634T301 REV 93 PART 6 SUB 51-00-19 AND MM 11-00-00 REV 97.