What was found
DURING ROUTINE C CHECK INSP FOUND BULK CARGO DOOR FWD SILL DENTED. REMOVED DAMAGED AREA. FOUND TO BE WITHIN LIMITS. PERFORMED NDT INSPECTION, NO CRACKS OR CORROSION NOTED. CLEANED, TREATED, PRIMED AND PAINTED IAW SRM 51-10-01, 51-20-01 REV101, 53-00-01 FIGURE 101 REV101, NDT D634T301 REV93 PART6 SUB 51-11-19 AND MM 11-00-00 REV 97.