What was found
DURING ROUTINE C CHECK INSP FOUND NR 1 ENGINE OTBD PYLON DENTED JUST AFT OF HYD ACCESS DOOR. BLENDED OUT DENTS. FOUND TO BE WITHIN LIMITS. PERFORMED NDT INSP, NO CRACKS OR CORROSION NOTED. CLEANED, TREATED, PRIMED AND PAINTED IAW SRM 51-10-01, 51-20-01 REV101, 54-51-10 FIGURE 101 REV101, AND NDT D634T301 REV93 PART6 SUB 51-11-19.