What was found
DURING ROUTINE C CHECK INSP FOUND GOUGES IN SKIN AT AFT CARGO DOOR AT 27R E58 3417771. BLENDED OUT GOUGES. FOUND TO BE WITHIN LIMITS. PERFORMED NDT INSP, NO CRACKS OR CORROSION NOTED. CLEANED, TREATED, PRIMED AND PAINTED IAW SRM 51-10-01, 51-20-01 REV101, 52-30-01 FIGURE 101 REV 101, NDT D634T301 REV93 PART6 SUB 51-11-19 AND MM 11-00-00 REV 97.