What was found
DURING ROUTINE C CHECK INSP, FOUND DENTS IN SKIN AT STA 1372 30R. BLENDED OUT DENTS. FOUND TO BE WITHIN LIMITS. PERFORMED NDT INSP, NO CRACKS OR CORROSION NOTED. CLEANED, TREATED, PRIMED AND PAINTED IAW SRM 51-10-01, 51-20-01 REV 101, 53-00-01 FIGURE 101 REV 101, NDT D634T301 REV 93 PART6 SUB 51-11-19 AND MM 11-00-00 REV 97.