What was found
DURING PRE DEPARTURE CHECK FOUND LT INBD T/E FLAP CRACKED. FABRICATED AND INSTALLED REPAIR IAW SRM 57-33-01, FIG 201. ACFT RETURNED TO SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING PRE DEPARTURE CHECK FOUND LT INBD T/E FLAP CRACKED. FABRICATED AND INSTALLED REPAIR IAW SRM 57-33-01, FIG 201. ACFT RETURNED TO SERVICE.