What was found
DURING TAKEOFF, THE CREW SMELLED A STRONG FUEL ODOR, THE PACKS WERE TURNED ON AND FUEL ODOR WENT AWAY. THE CREW LANDED WITHOUT FURTHER INCIDENT. MX INSPECTED FUEL SYS AND FOUND FUEL LEAK COMMING FROM CRACKED FASTENER ON THE RT TANK AT PYLON. THEY REPLACED AND RESEALED FASTENER IAW SRM 51-40-00 AND 51-20-05. LEAK CHECKED GOOD ON BOTH RT MAIN TANK AND CENTER TANK IAW AMM 28-11-00. ACFT RETURNED TO SERVICE.