What was found
DUIRNG ROUTINE C CHECK INSPECTION FOUND RIGHT VERTICAL STABILIZER TO FUSELAGE JOINT ANGLE CORRODED AT STA 1590. REMOVED CORROSION. FOUND OUT OF LIMITS. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGED AREA. FABRICATED ANGLE, SPLICE, FILLER AND SHIMS. PERFORMED HEAT TREATMENT. CLEANED, TREATED, PRIMED AREA AND REPAIR PARTS. INSTALLED NEW FASTENERS AND REPAIR PARTS IAW SRM 53-2-5 FIGURE 16A SHEETS ½, SRM 51-1-8, SRM 53-2-0, SRM 53-2-2 FIGURE 16A SHEETS 1-2, DPS 4.710 REV "L", SRM 51-1-6, SRM 51-1-8B, SRM 53-2-2, SRM 51-1-20D, AND SRM 51-3-1.