What was found
DURING ROUTINE C CHECK INSP FOUND MAIN CARGO COMPARTMENT FITTING CORRODED AT STA 879.000, LONGERON-19 RT TO LONGERON-22 RT. REMOVED CORROSION. FOUND OUT OF LIMITS. REMOVED DAMAGE FITTING. CLEANED, TREATED, PRIMED AREA AND REPAIRED PARTS. APPLIED SEALANT TO FRAYING SURFACES. INSTALLED NEW FITTING IAW SRM CHAP 53-1-0 PAGE 1, SRM 51-1-8, SRM 53-2-0, PAGE 2P, SRM 53-1-0, PAGE 1, SRM 51-1-20D, ATI REPAIR SPECIFICATION NR 2003-05, SMN-FORM-007 IPI NR 2011030, SRM 51-1-8B, SRM 51-1-11, SRM 51-1-20D, AND SRM 51-3-1.