What was found
DURING ROUTINE C-CHECK INSP FOUND RT MLG WHEEL WELL FITTING CRACKED AT STATION 920, LONGERON 24 RT. REMOVED CRACKED FRAME FITTING. FABRICATED SPLICERS, SHIMS AND DOUBLERS. CLEANED, TREATED, PRIMED AREA AND REPAIR PARTS. INSTALLED NEW FITTING AND REPAIR PARTS IAW SRM 51-1-20D, SRM 51-3-0, SRM 53-2-0, FIG 8, PAGE 53, SRM 53-2-0, FIG 8 SHEETS 1/3/6 PAGE 41/45-46/51-52 CONFIGURATION 501, DPS 4.710 REV "L", SRM 51-1-8B, SRM 51-9-0, AND SRM 51-3-1.