What was found
DURING ROUTINE C-CHECK INSP FOUND AFT ACCESSORY COMPARTMENT LONGERON 24 RT CORRODED AT STATION 1380.000 - 1400.000. REMOVED CORROSION. FOUND OUT OF LIMITS. REMOVED DAMAGED AREA. FABRICATED LANGERON AND SPLICERS. CLEANED, TREATED, PRIMED AREA AND REPAIR PARTS. INSTALLED REPAIR PARTS IAW SRM CHAP 53-2-2 FIG 10 SHEET 3 TR 53-193 SHEET 4, SRM 51-1-8, DC8 SRM 53-2-0, DC8 SRM 53-2-0 FIGURE 4, SRM 53-2-2 TR 53-193, SRM 53-2-2, FIG 4, SRM 53-4-1 FIG 44B, SHEET 2 ITEM "D", SRM 51-2-0, FIG 50 SHEET 51, SRM 51-2-0 FIGURE 51 SHEET 62, DPS 4.710 REV "L",. SRM 51-1-8B, SRM 53-2-2 FIG 10 SHEET 3, SRM 51-1-20D, AND SRM 51-3-1.