What was found
DURING ROUTINE C-CHECK INSP FOUND RT MLG WHEEL WELL FITTING CRACKED AT STATION 879.375. REMOVED CRACKED FRAME FITTING. FABRICATED NEW FITTING, SPLICERS, SHIMS AND DOUBLER. CLEANED, TREATED, PRIMED AREA AND REPAIR PARTS. INSTALLED NEW FITTING, DOUBLER, SPLICERS, AND SHIMS IAW SRM CHAP 53-2-0, FIG 8 SHEETS 1/3/6 PAGE 41/45-46/51-53, SRM 51-1-20D, SRM 53-1-0 PAGE 1, SRM 53-2-0, FIG 8 SHEETS 1/3/6 PAGE 41/45-46/51-52, DPS 4.710 REV "L", SRM 51-1-8B, SRM 51-9-0 TR 51-108 & TR 51-153, SRM 51-1-20D, SRM 51-3-0, AND SRM 51-3-1.