What was found
LOWER FWD ATTACH ANGLE ON WEB AT THE BOTTOM OF THE VERTICAL COMMON TO PANEL 324AL HAS A .50 CRACK. R & R ANGLE IAW DWG 173T1302. INSTALLED ANGLE IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LOWER FWD ATTACH ANGLE ON WEB AT THE BOTTOM OF THE VERTICAL COMMON TO PANEL 324AL HAS A .50 CRACK. R & R ANGLE IAW DWG 173T1302. INSTALLED ANGLE IAW SRM 51-40-02.