What was found
BULK CARGO DOOR AFT ENCLOSURE WEB CORRODED FROM FLOOR LEVEL UP 34 INCHES. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-0015. FABRICATED A NEW WEB IAW DRAWING 146T1281-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BULK CARGO DOOR AFT ENCLOSURE WEB CORRODED FROM FLOOR LEVEL UP 34 INCHES. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-0015. FABRICATED A NEW WEB IAW DRAWING 146T1281-4.