What was found
AFT LOWER CARGO FLOOR AT BS 1175 STRINGER 37 - 38L CORRODED SHEAR TIE. BLENDED THE CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-00-51.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT LOWER CARGO FLOOR AT BS 1175 STRINGER 37 - 38L CORRODED SHEAR TIE. BLENDED THE CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-00-51.