What was found
CORROSION FOUND ON THE AFT ENTRY FLOORBEAM 1682, LBL 30. REMOVED CORROSION AND INSTALLED A REPAIR DOUBLER IAW SRM 53-60-51, REPAIR 2, ALTERNATIVE 1, TABLE 1, FIG 201.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON THE AFT ENTRY FLOORBEAM 1682, LBL 30. REMOVED CORROSION AND INSTALLED A REPAIR DOUBLER IAW SRM 53-60-51, REPAIR 2, ALTERNATIVE 1, TABLE 1, FIG 201.