What was found
DURING SCHEDULED MAINTENANCE, EMERGENCY DOOR INDICATOR ILLUMINATED & EICAS MESSAGE DISPLAYED. DOOR VERIFIED CLOSED AND LATCHED SECURELY. PROXIMITY SWITCH ELECTRONIC UNIT (PSEU) BITE CHECK FLAGGED S192 SENSOR LIGHT. FOLLOWING TROUBLESHOOTING IAW WDM 52-71-12, LINE MAINTENANCE REPORTED, WIRE SHIELDING NEAR THE SPLICES DAMAGED. WIRING RESPLICED. EMERGENCY DOOR LIGHT & EICAS MESSAGE CLEARED, THE SENSOR LIGHT ON THE PSEU REMAINED. IAW FIM 32-09-FAULT TREE 803, R & R PROXIMITY SENSOR SWITCH S192 IAW AMM 52-71-01. NO FIX. IAW WIRING DIAGRAM MANUAL 52-71-12 & FIM 32-09-FAULT TREE 805, R & R PSEU. OPS CHECKED GOOD.