What was found
POST FLT, INBOUND CREW REPORTED LE SLAT ASSY ILLUMINATED ON FLAP EXTENSION. FLIGHT CONTINUED UNAFFECTED. LANDED WITHOUT INCIDENT. FOLLOWING VISUAL INSPECTS, MX REPORTED DAMAGE TO NR 8 SLAT. NR 8 SLAT DAMAGED. SLAT ASSY, ROTARY ACT, & OTBD LE SLAT G/B ASSY R & R IAW AMM 27-81-02, 27-81-00, & 27-81-20. NR 8 SLAT INBD & OTBD TRACKS CHKD GOOD. IAW MAINT OPS REQUEST, NR 8 INBD & OTBD SLAT ROLLER BEARINGS R & R. 621HB PANEL DAMAGED ALONG LE SIDE. PANEL ASSY 621HB R & R IAW AMM 20-11-00. 622DT BENT. NR 8 SLAT R & R IAW AMM 27-81-02. DUCT BETWEEN NR 8 & 9 SLATS DAMAGED. DUCT R & R IAW AMM 30-11-06. LEAK CHKD GOOD. ANTI-ICE DUCT CLOSE-OUT PANEL DAMAGED. DOOR ASSY R & R IAW AMM 57-41-58. RIG CHK GOOD. NR 9 SLAT RETAINER & SEAL DAMAGED. RETAINER & SEAL R & R IAW AMM 20-11-00. FIXED LE PANEL BENEATH NR 9 SLAT PUNCTURED. PANEL ASSY R & R IAW MM 51-40-02. FIXED LE PANEL NR 8 CRACKED. PANEL ASSY R & R IAW MM 51-40-02. ORIGINAL SUBMISSION DATE: 6/26/2025