What was found
CENTER PEDESTAL EMERGENCY FLASHLIGHT HOLDER BROKEN. MAINTENANCE PLACED ON DEFERRAL 65656 MINIMUM EQUIPMENT LIST 25-63-04-01 CATEGORY C. DUE 07 SEPTEMBER 2025. IN ACCORDANCE WITH B767 FIM 52-71 FAULT TREE 816 AND B767 WDM 52-71-12 BITE PROCEDURE FOR PROXIMITY SENSOR ELECTRONIC UNIT AND FAULTED CODE 005, 007, AND 219. INSPECTED AND CLEANED SENSOR S219. FAULT CLEARED. REMOVED AND REPLACED DEACTIVATION CHOKE S9013 ON TB101F (A191-C191) IAW B767 SWPM 20-90-15 AND IAI SUPPLEMENTAL WDM 52-71-12. OPERATIONAL CHECK GOOD. DEFERRAL 65652 CLEARED.