What was found
DURING ROUTINE C-CHECK INSPECTION, A CORRODED GUSSET AT FUSELAGE STATION 128 AND LONGERON 22 LEFT WAS FOUND. THE GUSSET WAS REMOVED, FABRICATED AND INSTALLED IN ACCORDNACE WITH THE DOUGLAS STRUCTURAL REPAIR MANUAL 53-1-0, AND FAA DER APPROVED SKETCH B68-R16.