What was found
DURING ROUTINE C-CHECK INSPECTION, THE RIGHT ELEVATOR TRAILING EDGE EXTERNAL PLATING WAS FOUND TO BE BULGING AT STATION XE122. REPAIR WAS ACCOMPLISHED BY REMOVAL OF THE DAMAGED AREA, FABRICATION AND INSTALLATION OF A NEW SECTION OF PLATING IN ACCORDANCE WITH DOUGLAS DRAWING SRO8550002, SRM 51-1-21, AND SRM 51-4-4.