What was found
DURING ROUTINE C CHECK INSPECTION, CORROSION WAS DETECTED ON RIGHT HORIZONTAL STABILIZER UPPER TRAILING EDGE PANEL BETWEEN STATIONS XE 272 AND XE 275. REPAIR ACCOMPLISHED REMOVAL OF DAMAGED AREA, FABRICATION AND INSTALLATION OF A NEW PANEL IN ACCORDANCE WITH FAA DER APPROVED DRAWING F03-R04 AND ENGINEERING ORDER 55-DC8-927.