What was found
DURING ROUTINE C CHECK INSPECTION, CORROSION WAS DETECTED ON LEFT VERTICAL STABILIZER PANEL BETWEEN STATIONS ZR 253 AND ZR 297. REPAIR ACCOMPLISHED REMOVAL OF DAMAGED AREA, FABRICATION AND INSTALLATION OF A NEW PANEL IN ACCORDANCE WITH FAA DER APPROVED DRAWING E68-R01 AND ENGINEERING ORDER 55-DC8-892.