What was found
DISCOVERED CORROSION ON LEFT AND RIGHT WING WEDGE PANEL IB TRAILING EDGE BOX PANEL INTERFACE. GAINED ACCESS TO CORRODED LH AND RH WEDGE ANGLES. REPLACED MATCH DRILLED WEDGE ANGLES. WORK COMPLETED IAW GAC DRAWINGS 1159W40166 REV D. 1159W40003 REV N. AND 1159W20201 REV L. REINSTALLED ALL REMOVED COMPONENTS FOR ACCESS. COMPLIED WITH ALL REQUIRED OPS CHECKS. APPLIED TOPCOAT FOR UPPER SURFACE OF WING IAW G450 SRM 51-07-10.