What was found
GENERATOR 1 FAILED AT FL430 AFTER LANDING AT KPRB. ENGINE 1 LOST ALL OIL. REPLACED FAILED LH GENERATOR. REPLACED DAMAGED LTD. WORK COMPLETED IAW EMB PRAETOR AMM 24-31-01. INSTALLED REPLACEMENT BEARINGS ONTO #1 ENGINE GENERATOR AGB GEAR SHAFT IAW HONEYWELL AS907-3-1E LMM 72-61-01. REPLACED #1 ENGINE AGB GENERATOR CARBON SEAL IAW AS907-3-1-E LMM 12-61-01. OPS AND LEAK CHECKS GOOD. PERFORMED ENGINE POWER RUNS. ALL OPS AND LEAK CHECKS ARE SATISFACTORY AT THIS TIME. INSPECTED AGB DEBRIS MONITORS POST ENGINE RUNS AND NOTED NO DEFECTS.