SDR JBXA00016

Service difficulty report · Outflow Vlv · Fokker F28MK0100

Difficulty date
August 6, 1996
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N109ML
Make and model
Fokker F28MK0100
Aircraft serial
11485
Part
Outflow Vlv
Part number
1037223
Condition
Failed
Location
Cabin
Part time
4,600 hours
Stage of operation
CR
Nature of condition
J
Precautionary procedure
G

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RDU - FLT 901 - LOST CABIN PRESSURIZATION CONTROL. BOTH CABIN PRESSURE CONTROLLERS FAULTED, TRIED TO CONTROL MANUALLY WITH NO RESPONSE. ALL OXYGEN MASKS DEPLOYED. REPLACED PRIMARY OUTFLOW VALVE IAW AMM 21-51-03. OPS CHECK OF AUTO AND MANUAL SYSTEM GOOD. (M)