SDR JBXA000276

Service difficulty report · Warning Light · Fokker F28MK0100

Difficulty date
April 30, 2001
Submitted
May 1, 2001
Operation
Air carrier
Aircraft
N106ML
Make and model
Fokker F28MK0100
Aircraft serial
11477
Aircraft time
21,116 hours, 15,178 cycles
Part
Warning Light
Condition
Illuminated
Location
Cockpit
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WHEN LEVELING AT 31,000 FT JAMMED STAB AMBER WARNING ON MFDU. PERFORMED AFCAS TEST IAW AMM 22-11-00, NO FAULTS FOUND. OPERATIONAL CHECK OF FLIGHT CONTROL SERVO VALVES STICKING CIRCUIT IAW AMM 27-00-00 AND OPERATIONAL TEST OF STABILIZER JAM SWITCH IAW AMM 27-43-00, NO FAULTS FOUND. CLEANED AND REINSTALLED JAM SWITCH CANNON PLUG, ALL OPS CHECKS GOOD.