What was found
DURING AMT TROUBLESHOOTING OF THE NR 1 ENGINE ALTERNATOR INTERMITTENT, DISCOVERED CRANKCASE STUDS BROKEN, UNRELATED TO THE ALTERNATOR ISSUE, INITIATED THE DISASSEMBLY AND REMOVED CYLINDER, ALL NON-DESTRUCTIVE TESTING CHECKS OK, REPLACING THE STUDS, ALSO REPLACING BROKEN TERMINAL AT THE ALTERNATOR TO FIX THE ALTERNATOR ISSUE.