What was found
MECHANICALLY BLENDED 8 AREAS CORROSION ON LT AND RT HORIZONTAL STAB PIVOT FITTINGS 6631102-29 AND -30, PERFORMED ULTRASONIC AND EDDY CURRENT INSPECTIONS AND REPORTED TO ENGINEERING FOR DISPOSITION. CLEANED TREATED, PRIMED AND TOP COATED AREAS PER REPAIR MEMO.