What was found
FOUND SEVERAL AREAS OF CONFIRMED CORROSION UNDER SEVERAL NUTPLATES ON THE V-STAB AT THE FOLLOWING LOCATIONS: 341DL 7 NUTPLATES, 341CL 5 NUTPLATES,341BL 5 NUTPLATES, 341DR 3 NUTPLATES,341CR 5 NUTPLATES, 341AL 1 NUTPLATE. REMOVE NUTPLATES AND BLEND CORROSION. PREP, TREAT AND PRIME AFTER NDT. BLENDED SEVERAL AREAS OF CORROSION UNDER SEVERAL NUTPLATES ON THE V-STAB AT THE FOLLOWING LOCATIONS: 341DL 7 NUTPLATES, 341CL 5 NUTPLATES, 341BL 5 NUTPLATES, 341DR 3 NUTPLATES, 341CR 5 NUTPLATES, 341AL 1 NUTPLATE. FOUND CORROSION TO BE OUT OF LIMITS, PER CESSNA 680 SRM 51-10-01 AND 51-70-02. SUBMITTED TO TEXTRON. REPAIRED CORROSION, PER TEXTRON MEMO DQ27778M1 DATED: NOVEMBER 11, 2020. CORROSION REMOVED WAS CONSIDERED TO BE LEVEL 2, PER NETJETS GMM 2.2.2.