As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WHILE PERFORMING TASK 57-00-00-2501 AN EDDY CURRENT INDICATION WAS FOUND IN THE CENTER SPAR LWS 6 FORWARD FASTENER HOLE IN THE SECOND LAYER OF MATERIAL. REMOVED FASTENER, REAMED HOLE OVERSIZE, PERFORMED NDT AND INSTALLED NEW FASTENER PER AQRD ENGINEERING REPAIR ORDER.