As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LIGHTENING STRIKE DAMAGE TO LT ELEVATOR, O/B TRAILING EDGE AT STATIC DISCHARGER. C/W (NDT) HFEC INSPECTION IAW ENGINEERING AUTHORIZATION 5-2010-253 AND NDT MANUAL PSM 1-82-7A, PART 1 51-00-06 WITH NO CRACKS OR HEAT DAMAGE NOTED. REPAIRED DAMAGED AREA IAW STS ENGINEERING SOLUTIONS 5-2010-253 AND RD8-55-938.