What was found
SERVICE DOOR THRESHOLD (BEAM) CORRODED AS MARKED FRM 20-22. REMOVED DAMAGE PART AND LOCATED, DRILLED, COUNTERSUNK, ALODINED AND INSTALLED NEW THRESHOLD FOR SERVICE DOOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SERVICE DOOR THRESHOLD (BEAM) CORRODED AS MARKED FRM 20-22. REMOVED DAMAGE PART AND LOCATED, DRILLED, COUNTERSUNK, ALODINED AND INSTALLED NEW THRESHOLD FOR SERVICE DOOR.